(back) Subject: Re:Blower From: "Hugh Knapton" <knapton@superaje.com> Date: Fri, 16 Nov 2001 07:50:50 -0400   Brian wrote: > I have a 3/4 horse Kinetic putting out a little less >than 3", which seems to be the max it will go.   Long shot here.... but I have encountered it more often than you would think possible. It is possible that that blower was only designed to give 3" w.p. BUT you may wish to make sure that it is in fact revolving in the correct direction. A blower will still give pressure, but usually considerably less if the rotation is backwards.   Hugh  
(back) Subject: Re: [Residence Organs] Re:Blower From: "Jimmy" <jrbaird@erols.com> Date: Fri, 16 Nov 2001 10:06:32 -0500   > Brian wrote: > > I have a 3/4 horse Kinetic putting out a little less > >than 3", which seems to be the max it will go. > I had a friend who once wired a Kinetic blower to a 110 volt line, when the blower motor was wired for 220 volts. Slow speed and low pressure was the result. After re-setting the wires on the motor for 110 volt operation, everything was fine.   jimmy used the previous